Wilden A100P
FLOW RATE 42.4 LPM (11.2 GPM)
MAX PRESURE = 8.6 BAR (125 PSI) WETTED HOUSINGS (Water Chambers and Manifolds)
| Material |
Ship Wt |
| PVDF |
5 kg (10 lbs) |
| Polypropylene. |
4 kg (8 lbs) |
NON-WETTED HOUSINGS
| Description |
Material |
| Center Section |
Polypropylene |
|
| Air Valve |
Polypropylene or Acetal |
MAXIMUM SUCTION LIFT CAPABILITY
6.6 mm (21.5)" Dry
MAXIMUM DIAMETER SOLIDS
1.6 mm
ELASTOMER OPTIONS
| Material |
Temperature Limits |
| Buna-N® |
-12.2 (+10) to +65.6 (+150) °C (F°) |
| Polyurethane |
-12.2 (+10) to +65.6 (+150) °C (F°) |
| Saniflex |
-28.9 (+20) to +104.4 (+220) °C (F°) |
| Teflon® PTFE |
+4.4 (+40) to +104.4 (+220) °C (F°) |
| Viton® |
-40 (-40) to +176.7 (+350) °C (F°) |
| Wil-Flex |
-40 (-40) to +107.2 (+225) °C (F°) |
| ENGINEERING OPERATION & MAINTENANCE MANUAL |
 |
A100P |
3880 k |
| |
|